What Is Auto Transformer Starters And How It Works

What would an Autotransformer Starter and how does it function?

Squirrel cage induction motors are often used with full line voltage and a DOL starter. This starter generates a large starting current, which might damage the motor windings and cause a current spike in the electricity system. As a result, an autotransformer starter, a different starting technique, is utilized to start a three-phase induction motor. This is mainly for induction motors coupled in a star or delta configuration. The decreased voltage starts in the electromechanical device are known as autotransformer starters. This starter can reduce inrush current within the distribution network to a lower level than all other electromechanical starters.

Auto Transformer Starters

Autotransformer starters are electrical control devices used to start three-phase induction motors. These starters work by gradually increasing the voltage applied to the motor, allowing it to ramp up to full speed smoothly and efficiently. Unlike other motor starters, auto transformer starters do not rely on mechanical switches or contacts to control the starting process. Instead, they use a combination of transformers, resistors, and capacitors to adjust the voltage supplied to the motor.

 This reduces stress on the motor and can help extend its lifespan. Autotransformer starters are also relatively compact, making them well-suited for tight or confined spaces. In addition, they can be used with various motor types, including those with low-voltage or high-starting torque requirements.

What is a Starter for an Autotransformer?

During the start-up phase, an autotransformer starter is often used to reduce the applied voltage. When large motors are utilized in a circuit for an extended period, a potential difference can occur, causing severe damage to electrical equipment connected to the same supply line. We know that current and voltage are proportionate to someone in form VI. When the voltage supply is reduced, the initial current is also reduced. As a result, many ways can be used to minimize the voltage. A transformer is one method of lowering the input signal to the electric motor.

Electric motor

The electric motor can be supplied the same reduced voltage until it reaches its average running speed. The lowered voltage can be supplied through the main maximum voltage line after the motor’s running speed has returned to normal.

However, it should be noted that the transformer used in this type of starter is not a standard step-down transformer with unique primary and secondary windings. This transformer has only one winding used for both input and output.

Production output

These transformers have several taps for producing outputs. In practice, autotransformer tapping can be done anywhere between 50% and 80%. As a result, these tapes are primarily utilized to provide various voltage options for triggering the motor. Compared to a traditional transformer with primary and secondary windings, the performance of all these motors is straightforward, with less weight and expense.

This transformer’s starter does not require complicated wiring because it is connected to the motor via three terminals. The machine is attached to the autotransformer’s output when it is triggered. The primary function of an autotransformer starter is to reduce the motor’s inputs regarding the squares of the transformer’s voltage ratio.

Autotransformer Starter Theory

The auto-transformer starter can be utilized with any squirrel cage induction motor that provides power to all three taps of the three-phase autotransformer starter. The motor can be directly coupled to the transformer’s secondary coil with this starter.

The auto-tap transformer’s cut off the starting voltage and supply to the motor at 50 percent, 65 percent, or 80 percent of a low voltage. Because the motor is attached to the secondary winding of something like the transformer starter’s continuous acceleration, the current flowing is always low compared to the motor armature voltage.

If the motor is attached to the transformer’s 50% tap, the motor current will be reduced to 50% of the modest beginning current. On the other hand, the line current will be just 25% of the modest initial current. The autotransformer in the circuit is responsible for the differences in motor and line current.

The preexisting autotransformer starter is often used to reduce the power starter due to the lower line. Because the motor covering the following is higher than the line power through with an autotransformer starter. The starter produces more torque per ampere of current flowing than any other type of voltage starter.

Read More: What Is Mouse Acceleration? And How To Turn Off The Mouse Acceleration?

Advantages

The following are some of the advantages of using an autotransformer starter.

  • Using this transformer, the inrush power can be reduced.
  • The starting voltage can be adjusted by finding the right tap on the transformers.
  • In comparison to the motor current, the current flowing is lower.
  • The excitation current is used less frequently.
  • This motor is suitable for large motors that cannot be started via the direct data connection. Large motors, especially those operated by a substantial load, cannot be driven with the star-delta.
  • This method is suitable for long initial periods.
  • This transformer ratio varies between 65 and 80 percent.
  • The maximum torque will be present for each amp of the current supply.
  • This transformer uses less copper in its construction.
  • It has a higher efficiency than the traditional one.
  • The voltage control is significantly improved.

Disadvantages

The following are some of the downsides of using an autotransformer starter.

  • The power factor is lower.
  • The circuit is pretty complicated and includes a relatively costly autotransformer.
  • The Korndorfer starter can indeed be attached to an operable machine if the gap is constrained due to its large size.

Applications

The following are examples of autotransformer applications.

  • It is used to lower the voltage of an induction motor’s starter.
  • Booster used at the end of a lengthy transmission line to compensate for line losses.
  • Used as a start-up device for specific fluorescent light fixtures.
  • In testing labs, autotransformers are employed in electrical devices.
  • Increases the voltages coming in.
  • Boosters are used in AC feeds to increase the necessary voltage level.
  • This transformer is utilized as a triggering component in induction and synchronous motors.
  • Induction motors with squirrel cages and slip rings are activated with this switch.
  • Used to link systems work at low voltage thresholds.

Both induction motors with a star and a delta connection can employ an autotransformer starter. Starting currents of 6 to 8 times the rated current can result in voltage drops in the power grid and severe torque surges that can harm both the motor and the attached equipment.

Complete voltage starter: what is it?

Full-voltage starters, also known as across-the-line starters or direct-on-line (DOL) start, attach the motor to a power line and are full-voltage non-reversing (FVNR). Only single-phase motors up to 5 HP at 320 VAC and three-phase engines up to 10 HP at 460 and 575 VAC can be started manually.

Apart from this, if you are interested to know more about Recycling Metals then visit our Featured category.

FAQ’s